सिभिल इन्जिनियरिङ
सिभिल इन्जिनियरिङ
Civil Engineering · ५,१७१ प्रश्न
५,१७१ प्रश्न उपलब्ध। मोड छान्नुहोस्:
सिभिल इन्जिनियरिङ: प्रश्न र उत्तर
सही लागेको विकल्पमा थिच्नुहोस्। सही भए हरियो, गलत भए रातो देखिन्छ; ३ सेकेन्डपछि सही उत्तर र व्याख्या देखिन्छ।
सही: ० / ०
-
In a UASB reactor, wastewater is treated by:
सही उत्तर: ग) Anaerobic bacteria in a sludge blanket through which wastewater flows upward
Upflow Anaerobic Sludge Blanket reactors pass wastewater up through a dense granular sludge bed; biogas is collected at the top.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
An Imhoff tank is a:
सही उत्तर: क) Two-storey tank with sedimentation in the upper compartment and sludge digestion in the lower
Settled solids slide through slots into the lower digestion chamber, so settling and digestion occur in one unit without mixing.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The main useful gas produced in anaerobic digestion of sewage sludge is:
सही उत्तर: घ) Methane
Digester gas contains roughly 60–70% methane (rest mainly CO2) and can be used as fuel.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A trickling filter in sewage treatment is an example of a(n):
सही उत्तर: ग) Attached-growth aerobic process
Microorganisms grow as a slime layer on stones or plastic media and oxidise organic matter as sewage trickles over them.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
In a 30-minute settling test, mixed liquor with MLSS 2500 mg/L gives a settled sludge volume of 250 mL/L. The sludge volume index is:
सही उत्तर: ग) 100 mL/g
SVI = settled volume (mL/L) × 1000/MLSS (mg/L) = 250 × 1000/2500 = 100 mL/g, indicating good settleability.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
An activated sludge plant treats 1000 m³/day of sewage with BOD 200 mg/L in an aeration tank of 500 m³ with MLSS 2000 mg/L. The F/M ratio is:
सही उत्तर: घ) 0.2 per day
F/M = Q·S0/(V·X) = 1000 × 200/(500 × 2000) = 0.2 kg BOD per kg MLSS per day.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The flow of sewage in sewers in the absence of storm water, i.e. the normal daily sewage flow, is called:
सही उत्तर: ग) Dry weather flow
Dry weather flow (DWF) is the average sewage flow during periods without rainfall.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The smoke test on a house drainage system is carried out to:
सही उत्तर: घ) Detect leaks and defective joints by forcing smoke into the closed drain
Smoke is pumped into the sealed drainage system; its escape at any point reveals leaks; the water (hydraulic) test is another tightness test.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
Vitrified clay (stoneware) pipes are favoured for small house sewers mainly because they:
सही उत्तर: ग) Resist corrosion by sewage acids and gases
Glazed stoneware is highly resistant to H2S-related corrosion and has a smooth interior, though it is brittle and weak in pressure.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A depressed sewer (inverted siphon) is provided where a sewer has to:
सही उत्तर: ख) Pass below an obstruction such as a river or deep cutting
An inverted siphon dips below obstacles and runs full under pressure, rising again on the far side.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
यी अभ्यास प्रश्न हुन्, आधिकारिक प्रश्न होइनन्। पाठ्यक्रम, विज्ञापन र नतिजाका लागि सम्बन्धित निकायको आधिकारिक वेबसाइट हेर्नुहोस्। उत्तरमा गल्ती भेटे प्रश्नमुनिको "टिप्पणी / गल्ती रिपोर्ट" मा लेख्नुहोस्।
नमस्ते! पाठ्यक्रम, सामान्य ज्ञान, भाषा परीक्षा वा कुनै प्रश्नको उत्तर बुझ्न सोध्नुहोस्।