The biological layer called 'schmutzdecke' forms on the top of a:
सही उत्तर: ख) Slow sand filter
In a slow sand filter a thin biological film forms on the sand surface and does most of the purification.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A settling tank of 500 m3 capacity treats 6,000 m3 of water per day. Its detention time is:
सही उत्तर: ग) 2 hours
Detention time = volume / flow = 500 / 6,000 day = 2 hours.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A rectangular sedimentation tank is 15 m long and 8 m wide and treats 4,800 m3/day. Its surface overflow rate is:
सही उत्तर: घ) 40 m3/m2/day
Surface overflow rate = Q / plan area = 4,800 / (15 x 8) = 40 m3/m2/day.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
According to Stokes' law, the settling velocity of a small discrete particle in water is proportional to:
सही उत्तर: घ) The square of the particle diameter
Stokes' law gives Vs = g(Gs - 1)d^2/(18 nu), so settling velocity varies with d squared.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
In water treatment, flocculation is achieved by:
सही उत्तर: क) Slow, gentle mixing that lets small particles join into larger flocs
Gentle stirring makes destabilised particles collide and grow into settleable flocs without breaking them.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The optimum dose of coagulant for a given raw water is determined in the laboratory by the:
सही उत्तर: ख) Jar test
In the jar test, samples are dosed with different amounts of coagulant to find the most effective dose.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
Turbidity of water measured by a nephelometer is expressed in:
सही उत्तर: ग) NTU
A nephelometer measures scattered light, and the result is reported in Nephelometric Turbidity Units (NTU).
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A water sample contains 60 mg/L of Ca2+ and 24.3 mg/L of Mg2+. Its total hardness expressed as CaCO3 is:
सही उत्तर: ग) 250 mg/L
Ca gives 60 x 50/20 = 150 and Mg gives 24.3 x 50/12.15 = 100, so the total is 250 mg/L as CaCO3.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
Hardness of water can be removed by the base-exchange method using:
सही उत्तर: घ) Zeolite
Zeolite exchanges its sodium ions for the calcium and magnesium ions that cause hardness.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
Temporary hardness of water is caused mainly by:
सही उत्तर: क) Bicarbonates of calcium and magnesium
Bicarbonate hardness can be removed by boiling, so it is called temporary hardness.
💬 टिप्पणी / गल्ती रिपोर्ट (०)