The RMS value of the voltage v = 100 sin(314t) volts is about:
सही उत्तर: ख) 70.7 V
V_rms = Vm / sqrt 2 = 100 / 1.414 = 70.7 V.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
An alternating voltage is given by v = 100 sin(314t) volts. Its frequency is about:
सही उत्तर: क) 50 Hz
w = 2 pi f = 314, so f = 314 / (2 x 3.14) = 50 Hz.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
Given v1 = Vm sin(wt) and v2 = Vm sin(wt + 30°), which statement is correct?
सही उत्तर: ग) v2 leads v1 by 30°
A positive phase angle (+30°) in the argument means v2 reaches its peak earlier, i.e. it leads v1 by 30°.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The low lagging power factor of an industrial installation is commonly improved by connecting:
सही उत्तर: ख) capacitors in parallel with the load
Shunt capacitors supply leading reactive power that offsets the lagging reactive power of inductive loads.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
At resonance, the impedance of an ideal parallel LC (tank) circuit is:
सही उत्तर: ख) maximum
In a parallel resonant circuit the branch currents cancel, so line current is minimum and impedance is maximum.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The resonant frequency of a series LC circuit is given by:
सही उत्तर: ग) 1 / (2 pi sqrt(LC))
Resonance occurs when 2 pi f L = 1 / (2 pi f C), giving f0 = 1 / (2 pi sqrt(LC)).
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
At resonance in a series RLC circuit, the impedance of the circuit is:
सही उत्तर: क) minimum and equal to R
At resonance X_L = X_C and they cancel, leaving Z = R, the minimum value, so current is maximum.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The average power consumed over a full cycle by an ideal (pure) inductor connected to an AC supply is:
सही उत्तर: क) zero
With a 90° phase difference, cos phi = 0; energy stored in one quarter-cycle is returned in the next, so average power is zero.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A load draws 10 kVA at a power factor of 0.8 lagging. Its active power is:
सही उत्तर: क) 8 kW
P = S x cos phi = 10 x 0.8 = 8 kW.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
The unit of reactive power is the:
सही उत्तर: ग) volt-ampere reactive (VAR)
Reactive power Q = V I sin phi is measured in VAR; apparent power is in VA and active power in W.
💬 टिप्पणी / गल्ती रिपोर्ट (०)