A transformer operates at maximum efficiency when its:
सही उत्तर: घ) copper loss equals its iron loss
Efficiency is maximum when the variable (copper) loss equals the constant (iron) loss.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A transformer delivers 20 kW with an iron loss of 400 W and a copper loss of 600 W. Its efficiency is about:
सही उत्तर: क) 95.2%
η = 20/(20 + 0.4 + 0.6) = 20/21 ≈ 95.2%.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A transformer is designed for 5 volts per turn. The number of turns needed for a 400 V secondary is:
सही उत्तर: ख) 80
N = 400/5 = 80 turns.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A transformer winding of 300 turns links a sinusoidal flux of maximum value 4 mWb at 50 Hz. The RMS emf induced in it is about:
सही उत्तर: ख) 266 V
E = 4.44fNΦ_m = 4.44 × 50 × 300 × 0.004 ≈ 266 V.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
In a balanced three-phase star-connected system with a line voltage of 11 kV, the phase voltage is about:
सही उत्तर: क) 6.35 kV
V_ph = V_L/√3 = 11/1.732 ≈ 6.35 kV.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A 2-pole alternator must run at what speed to generate 50 Hz?
सही उत्तर: घ) 3000 rpm
N = 120f/P = 120 × 50/2 = 3000 rpm.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A balanced three-phase load draws 100 A from an 11 kV line at 0.9 power factor. The active power is about:
सही उत्तर: ग) 1715 kW
P = √3 V_L I_L cos φ = 1.732 × 11000 × 100 × 0.9 ≈ 1.715 × 10⁶ W.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
In the two-wattmeter method for a balanced load, the readings are 5 kW and 3 kW. The power factor of the load is about:
सही उत्तर: ग) 0.92
tan φ = √3(W₁ − W₂)/(W₁ + W₂) = √3 × 2/8 = 0.433, so φ ≈ 23.4° and cos φ ≈ 0.92.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
In the two-wattmeter method, the readings are W₁ = 5 kW and W₂ = −1 kW (after reversing the second meter's connections). The total power is:
सही उत्तर: क) 4 kW
P = W₁ + W₂ = 5 + (−1) = 4 kW.
💬 टिप्पणी / गल्ती रिपोर्ट (०)
-
A balanced delta-connected load draws a line current of 17.32 A. The current in each phase of the load is:
सही उत्तर: घ) 10 A
In delta I_L = √3 I_ph, so I_ph = 17.32/1.732 = 10 A.